Vent Free Wall Heater Installation

This heater is designed for vent-free op - eration. State and local codes in some areas prohibit the use of vent-free heaters. State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas-sachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall. Before You Begin. Vent-free gas space heaters are available in several cabinet sizes, ranging from compact units sufficient for a small bath to fireplace-like models for large rooms.Most units can be wall-mounted or stand alone on optional bases. Depending on the size you choose, heat output can range from around 3,000 to 30,000 Btus per hour.

PRODUCT FEATURES

This 10,000 BTU Vent Free Blue Flame wall heater is perfect for bedrooms or rooms of 300 square feet or more. This thermostatically controlled wall unit requires no electricity and has no additional accessories. This allows for efficient operation while providing an alternate heat source during power failures. The dual fuel version of this heater allows the professional installer to set up the unit for either propane gas or natural gas. The dual fuel heater comes with an auto fuel detection system to sense which gas is coming into the heater. This heater is also available in single fuel in some markets.

Natural Gas Wall Heaters Vent Free

This heater has an enclosed blue flame for maximum safety while a second stainless steel front panel adds to the high end appeal of the unit. We recommend using a ceiling fan or air vents for maximum air circulation. This heater meets the latest ANSI standards for vent free operation (ANSI Z21.11.2-2013). A certified technician is required for installation. The warranty is void if the heater is not professionally installed.This heater is not designed to be used as a central heating system. The required room size is based on the room that the heater is installed in. Adjoining rooms cannot be counted towards the minimum square footage needed for this heater. CSA Certified.

Thermostat Control

For efficiency, our wall heater comes with a built-in thermostat. The control has settings 1 (low) through 5 (high), which determine how long the burner will stay on to reach your desired temperature. There is no exact temperature setting on the heater because each room size is different, so you will need to run the heater at a specific setting to determine what temperature the number on the dial gives you for your unique space. The copper bulb located on the back of the heater can be adjusted if needed to provide even better accuracy, although this is not typically needed. Please keep in mind that if the thermostat has reached the temperature of a particular setting, the burner will remain off until the room cools. (For example, setting 2 may only keep the pilot on if the room is warm enough.)

Vent Free Wall Heater Installation

Gas Connection

Our wall heaters have a built in regulator with a 3/8 inch male flare that requires a 3/8 inch female UNF connection to a 1/2 inch gas flex hose. The flex hose should be connected to a MINIMUM ½ inch gas line to ensure proper pressure. You must have a shut off valve installed on the gas line near the heater. Click HERE to purchase a kit that will provide the flex hose, fittings, and shut off valve all in one.

Blower

Traditionally vent free heaters have come with a blower. Our heater design eliminates the need for a blower because we have a closed burner chamber that pulls the air from the bottom of the heater forces it through the chamber and out the top vent at a 45 degree angle. We have found that this is more effective than having a blower and eliminates the need for electricity and moving parts. Our heater cannot be modified to add a blower after purchase.

Floor Mounting & Feet

While other similar products in the market place offer floor stands or “feet” our first priority at Thermablaster is safety. It is our philosophy that placing a WALL HEATER on the floor is not a safe decision and as a result we do NOT offer floor stands. Our wall heaters need 18 inches of clearance from the floor in order to operate properly and draw air through the bottom vent.

Vent Free Radiant Heater

**NOT FOR SALE OR USE IN THE STATE OF CALIFORNIA**

Vent Free Gas Wall Heater

The chart below will help you decide which heater is most appropriate for your application. Having too large of a heater in a too small of a space can cause the Oxygen Depletion Pilot (ODS) to shut off the burner and the pilot due to low oxygen levels.

Recommended ModelsWDFT060-VF (Dual Fuel)

WNT060-VF (Natural Gas)

WLT060-VF (Propane)

WDFT100-VF (Dual Fuel)

WNT100-VF (Natural Gas)

WLT100-VF (Propane)

WDFT320-VF (Dual Fuel)

WNT320-VF (Natural Gas)

WLT320-VF (Propane)

BTU Output6,000 BTU10,000 BTU32,000 BTU
Minimum Room Size150 Square Feet minimum or more300 Square Feet minimum or more1,100 Square Feet minimum or more
Room TypeMaximum size for bathroomsMaximum size for bedroomslarge rooms & garages of 1,100 square feet or greater. NOT allowed in Bathrooms or Bedrooms

Thermablaster Vent Free Wall Heater Installation

REPLACEMENT PARTS

Gas Wall Heater Installation

Please click HERE to order replacement parts for your heater. Please note your model number, serial number, and contact information in your request.